How this calculation works
For each setpoint, multiply the above-outdoor temperature difference by the heat loss coefficient and heating hours. Reprice the resulting useful heat.
How to use your result
The same one-degree change has different effects in different homes and weather. Keep health, comfort and household needs in mind.
Assumes one average outdoor temperature, fixed heating hours and constant heat loss. It does not include warm-up or thermal gains.
Worked example
With 180 W/K of heat loss, a one-degree reduction over 1,000 heating hours reduces modelled useful heat by 180 kWh.
Starting assumptions
- Existing setpoint · 21 °C
- New setpoint · 20 °C
- Average outdoor temperature during heating hours · 8 °C
- Home’s heat loss coefficient · 180 W/K
- Hours scheduled per day · 4 hours
- Days used over the period · 90 days
- Electric system efficiency · 100 %
- Seasonal boiler efficiency · 88 %
- Seasonal performance factor · 3 ratio
The examples give you a starting point. Use your own measurements and tariffs for a decision.