How this calculation works
Multiply area by the reduction in U-value and heating degree days, then multiply by 24 and divide by 1,000 for useful kWh saved.
How to use your result
Lower U-values mean less heat loss. Use measured or documented property values and comparable local degree-day data.
Simplified steady-state estimate for the upgraded area. It omits air leakage, damp, occupants and interaction with other measures. A professional assessment is needed for design.
Worked example
A 50 m² surface improved from 0.8 to 0.2 W/m²·K reduces heat loss by 30 W/K.
Starting assumptions
- Surface being upgraded · 50 m²
- Existing U-value · 0.8 W/m²·K
- Improved U-value · 0.2 W/m²·K
- Annual heating degree days · 2100 K·days
- Electric system efficiency · 100 %
- Seasonal boiler efficiency · 88 %
- Seasonal performance factor · 3 ratio
- Project cost after any confirmed grant · 3000 £
The examples give you a starting point. Use your own measurements and tariffs for a decision.