How this calculation works
Add each surface’s area × U-value. Estimate ventilation heat loss as 0.33 × heated volume × air changes per hour, then multiply all losses by the temperature difference.
How to use your result
Use net exposed wall area after subtracting doors and windows. Use the result to compare input changes and plan what to ask a heating designer.
Indicative whole-home heat loss only. Thermal bridges, ground heat flow and room-by-room heating system sizing require professional calculations.
Worked example
A 10 m² window area at 1.5 W/m²·K loses 300 W across a 20°C temperature difference.
Starting assumptions
- walls net exposed area · 65 m²
- walls U-value · 0.6 W/m²·K
- windows net exposed area · 18 m²
- windows U-value · 1.6 W/m²·K
- roof net exposed area · 50 m²
- roof U-value · 0.2 W/m²·K
- floor net exposed area · 50 m²
- floor U-value · 0.35 W/m²·K
- Heated internal volume · 220 m³
- Estimated air changes per hour · 0.7 1/hour
- Indoor temperature · 20 °C
- Outdoor temperature · -3 °C
The examples give you a starting point. Use your own measurements and tariffs for a decision.