How this calculation works
Multiply floor area by useful output per square metre, daily hours, duty cycle and days. Convert to kWh and apply the selected heat-source efficiency.
How to use your result
Water-based underfloor heating can be supplied by a boiler or heat pump. Use the selected system’s performance and keep the same useful output when comparing.
This is an operating scenario. It does not model floor construction, warm-up behaviour, installation costs or safe floor temperatures.
Worked example
25 m² delivering 60 W/m² for four hours delivers 6 kWh of useful heat before applying a cycling assumption.
Starting assumptions
- Heated floor area · 25 m²
- Useful output per heated square metre · 60 W/m²
- Hours scheduled per day · 4 hours
- Days used over the period · 90 days
- Share of scheduled time drawing full power · 65 %
- Electric system efficiency · 100 %
- Seasonal boiler efficiency · 88 %
- Seasonal performance factor · 3 ratio
The examples give you a starting point. Use your own measurements and tariffs for a decision.
Sources
- DESNZ Home Energy Model technical documentation
- Energy Technology List seasonal heat pump performance
Methodology reviewed · Revision 1