Understanding home battery efficiency and degradation

If 5 kWh goes in and 4.5 kWh comes back, the round-trip efficiency for that charge is 90%. If a battery once held 5 kWh and years later holds 4 kWh under the same test, it retains 80% of its original capacity. Those two percentages answer different questions.

· Published · Reviewed

Where was the electricity measured?

Divide energy returned by energy supplied, measured across a complete charge and discharge. In the example above, 4.5 divided by 5 gives 90%. Ask the installer to mark the input and output points used for their figure. A cell-only result leaves out equipment between the cells and your house. For example, Tesla’s UK Powerwall 2 data sheet specifies an AC-to-AC round trip at the start of life and names the test temperature and charge/discharge power. Use the sheet for the actual model you are offered. Comparing a panel-to-house figure from one system with a battery round trip from another tells you little.

What can you claim if it stores less?

Find the warranty that applies to your model and country. Write down its start date, the minimum capacity promised, the uses it covers and any limit on total energy delivered. Throughput is the running total of energy across many cycles. Ask whether the warranty counts energy charged or discharged and whether your intended use changes the limit.

For an example of the distinction, imagine a warranty covering at least 80% of a 10 kWh starting capacity at a stated date. The threshold would be 8 kWh. That says nothing about how many of today’s charging units come back this evening. Keep the commissioning record and ask how the manufacturer would test a capacity claim.

Sources and further reading

Browse battery storage

How to report an error or outdated information