How this calculation works
Multiply installed peak kW by roof-plane irradiation and the retained fraction after losses, then distribute output using monthly weights or a verified profile.
How to use your result
For a location-specific estimate, copy annual in-plane irradiation and monthly shares from a model for your roof angles. The manual weights are a seasonal example and can be changed.
The illustrative monthly profile is not a forecast. Verified generation profiles are valid only for their specific angles and losses.
Worked example
A 4 kWp system at 1,000 kWh/m² annual in-plane irradiation with 14% losses yields an estimated 3,440 kWh.
Starting assumptions
- Installed solar capacity · 4 kWp
- Verified location profile number · 1 profile
- Annual plane-of-array solar irradiation for your location, orientation and tilt · 1000 kWh/m²
- Roof tilt from horizontal · 35 °
- Orientation from south (east negative, west positive) · 0 °
- Total system losses · 14 %
- January share of irradiation · 3 %
- February share of irradiation · 5 %
- March share of irradiation · 8 %
- April share of irradiation · 11 %
- May share of irradiation · 13 %
- June share of irradiation · 13 %
- July share of irradiation · 13 %
- August share of irradiation · 11 %
- September share of irradiation · 9 %
- October share of irradiation · 7 %
- November share of irradiation · 4 %
- December share of irradiation · 3 %
The examples give you a starting point. Use your own measurements and tariffs for a decision.
Sources
Methodology reviewed · Revision 1